Applent AT3817D - LCR meter 100kHz , 100kHz
Review: 5 - "A masterpiece of literature" by , written on May 4, 2006
I really enjoyed this book. It captures the essential challenge people face as they try make sense of their lives and grow to adulthood.

Applent AT3817D - LCR meter 100kHz , 100kHz

Available: Out of Stock
€1.059,57

Brand: Applent Instruments

Properties:

  • Model Number: AT3817D
  • Frequency: 50Hz-100kHz (10 frequency points)
  • Signal level: 0.01 V - 2.00 V (10 mV step)
  • Power supply: voltage: 90 V AC - 250 V AC, frequency: 50 Hz - 60 Hz, power: max. 20 VA

Bond: housewares

Parameters

  • Cs-Rs, Cs-D, Cp-Rp, Cp-D,Lp-Rp, Lp-Q, Ls-Rs,
  • Ls-Q, G-B, R-X, Z-θrad, Z-θdeg, DCR
  •  Monitor Parameters Z, D, Q, θr, θd, R, X, G, B, Y, Vac, Iac, Δ, Δ%
  • Accuracy 0.05% ±5 dgt
  • Frequency 50Hz - 100kHz (10 frequency points)
  • Display Range L: 0.00001μH-999999H
  • C: 0.00001pF - 999999μF
  • R,Z: 0.00001 - 99.9999MΩ
  • D: 0.00001 - 9.99999
  • Q: 0.00001 - 99999.9
  • θ(deg): -179.999 °-179.999 °
  • θ(rad): -3.14159 – 3.14159
  • Δ%: -999999% - 999999%
  • DCR: 0.00001Ω ~ 99.9999MΩ
  • Source Resistance 30Ω, 50Ω, 100Ω
  • Range 9 ranges Automatic, Manual, Nominal
  • Max Reading principle parameter: 999999;
  • sub parameter: 999999
  • Signal Level 0.01V - 2.00V (10mV Step)
  • Speed 30 times/second, 10 times/second,
  • 6 times/second, 3 times/second
  • 1 - 256 times average is available
  • Comparator 14-bin sorting, 10-bin GD, 1-bin NG, 1-bin AUX,
  • 2-bin principle parameter NG
  • Adjustment Open/Short sweep frequency reset,
  • 3 point frequency and load correction
  • Files 10 group files to save users' setting,
  • 1 group system data save real-time

Interface

  • RS232C, ExHandler Interface,
  • standard USB disc interface (article 10000 data)
The newly upgraded AT3817A adopt true color TFT-LCD display and full Chinese operation interface (configurable into English). Displayed in large fonts, readings are more intuitive, used for laboratory quality control, feed inspection and component sorting. AT3817A with continuous frequency point of 50Hz~100kHz with a resolution of 0.001Hz. Test signal level 0.01Vrms ~ 2.00Vrms (10mV step), (add DCR measurement and internal DC bias (DC BIAS, ±2.5V) compared to AT28 series)
AT3817A can test the 4 parameters of the component at the same time. Each parameter can be arbitrarily configured. The newly improved instrument realizes full 6-bit display of the main and auxiliary four parameters. It can scan 10 kinds of frequencies or level lists, it can also be used for 3 groups users frequency be corrected to improve accuracy. Built-in comparator, through HANDLER interface combined with PLC to complete automatic sorting of components.
Test parameters: L, C, R, Z, D, Q, θ (deg), θ (rad), Vm, Im; Accuracy: 0.05%, 3.5 吋 Liquid crystal display: Main 999999 Sub 999999 Test frequency: 50~100kHz 16 frequency point; level: 0.01V~2.00V in 10mv step, output impedance: 30/50/100Ω
Function: three parameters display, up to 30 times / sec, 20 groups of records, 14 files sorting, RS232 and ExHandler interface

Brand: Applent Instruments

Properties:

  • Model Number: AT3817D
  • Frequency: 50Hz-100kHz (10 frequency points)
  • Signal level: 0.01 V - 2.00 V (10 mV step)
  • Power supply: voltage: 90 V AC - 250 V AC, frequency: 50 Hz - 60 Hz, power: max. 20 VA

Bond: housewares

Parameters

  • Cs-Rs, Cs-D, Cp-Rp, Cp-D,Lp-Rp, Lp-Q, Ls-Rs,
  • Ls-Q, G-B, R-X, Z-θrad, Z-θdeg, DCR
  •  Monitor Parameters Z, D, Q, θr, θd, R, X, G, B, Y, Vac, Iac, Δ, Δ%
  • Accuracy 0.05% ±5 dgt
  • Frequency 50Hz - 100kHz (10 frequency points)
  • Display Range L: 0.00001μH-999999H
  • C: 0.00001pF - 999999μF
  • R,Z: 0.00001 - 99.9999MΩ
  • D: 0.00001 - 9.99999
  • Q: 0.00001 - 99999.9
  • θ(deg): -179.999 °-179.999 °
  • θ(rad): -3.14159 – 3.14159
  • Δ%: -999999% - 999999%
  • DCR: 0.00001Ω ~ 99.9999MΩ
  • Source Resistance 30Ω, 50Ω, 100Ω
  • Range 9 ranges Automatic, Manual, Nominal
  • Max Reading principle parameter: 999999;
  • sub parameter: 999999
  • Signal Level 0.01V - 2.00V (10mV Step)
  • Speed 30 times/second, 10 times/second,
  • 6 times/second, 3 times/second
  • 1 - 256 times average is available
  • Comparator 14-bin sorting, 10-bin GD, 1-bin NG, 1-bin AUX,
  • 2-bin principle parameter NG
  • Adjustment Open/Short sweep frequency reset,
  • 3 point frequency and load correction
  • Files 10 group files to save users' setting,
  • 1 group system data save real-time

Interface

  • RS232C, ExHandler Interface,
  • standard USB disc interface (article 10000 data)
The newly upgraded AT3817A adopt true color TFT-LCD display and full Chinese operation interface (configurable into English). Displayed in large fonts, readings are more intuitive, used for laboratory quality control, feed inspection and component sorting. AT3817A with continuous frequency point of 50Hz~100kHz with a resolution of 0.001Hz. Test signal level 0.01Vrms ~ 2.00Vrms (10mV step), (add DCR measurement and internal DC bias (DC BIAS, ±2.5V) compared to AT28 series)
AT3817A can test the 4 parameters of the component at the same time. Each parameter can be arbitrarily configured. The newly improved instrument realizes full 6-bit display of the main and auxiliary four parameters. It can scan 10 kinds of frequencies or level lists, it can also be used for 3 groups users frequency be corrected to improve accuracy. Built-in comparator, through HANDLER interface combined with PLC to complete automatic sorting of components.
Test parameters: L, C, R, Z, D, Q, θ (deg), θ (rad), Vm, Im; Accuracy: 0.05%, 3.5 吋 Liquid crystal display: Main 999999 Sub 999999 Test frequency: 50~100kHz 16 frequency point; level: 0.01V~2.00V in 10mv step, output impedance: 30/50/100Ω
Function: three parameters display, up to 30 times / sec, 20 groups of records, 14 files sorting, RS232 and ExHandler interface