Applent AT9005 - Hipot Tester AC and DC Dielectric Strength Tester
Review: 5 - "A masterpiece of literature" by , written on May 4, 2006
I really enjoyed this book. It captures the essential challenge people face as they try make sense of their lives and grow to adulthood.

Applent AT9005 - Hipot Tester AC and DC Dielectric Strength Tester

Available: Out of Stock
€7.599,72

Brand: Applent Instruments
 
Properties:

  • Joint testing of six functions of pressure, insulation, grounding, leakage, power and commissioning (6 of 5)
  • Equipped with a PLC control interface, a variable frequency power supply control interface, a communication interface, etc., they can be automatically tested by external supporting facilities.
  • Higher reaction and test speed, the minimum setting is 0.5 seconds;
  • 1.5-level safety test accuracy, 0.5-level electrical parameter test accuracy;
  • The lower limit can be set to prevent product defect detection; for product test failure, intelligent analysis, sound and light alarm.

Bond: housewares

  • AC output voltage Range: 100-5000V, 50Hz/60Hz dual frequency optional, resolution: 1V, accuracy ± (1.5% set value +3V)
  • Current measurement 0.002-9.999-40.00mA, resolution: 0.001mA/0.01mA, accuracy: ± (1.5% read +0.005mA)
  • Current alarm setting range Upper limit: 0.001-40.00mA, lower limit: 0.00-40.00mA
  • AC withstand voltage test time Range: 1 ~ 999s Resolution: 1s
  • DC output voltage Range: 100-1000V continuously adjustable, resolution: 1V, accuracy: ± (1.5% set value +3V)
  • Insulation resistance measurement 100-499V: <;100MΩ: ± (5% reading + 0.5MΩ); 100MΩ-1000MΩ: ± (10% reading + 5MΩ) 500-1000V: <;100MΩ: ± (2% reading + 0.2MΩ ); 100MΩ-3000MΩ: ± (5% reading + 2MΩ)
  • Insulation resistance alarm setting range Upper limit: 1 ~ 2000MΩ; Lower limit: 0 ~ 2000MΩ
  • Insulation resistance test time Range: 1 ~ 999s Resolution: 1s
  • Grounding resistance output AC current Range: 5-30A continuously adjustable output, 50/60Hz dual frequency optional, resolution: 0.01A accuracy: ± (2% set value +0.20A)
  • Grounding resistance measurement range Range: 10.0~600mΩ Accuracy: 1.5% reading +3mΩ, resolution: 1mΩ
  • Grounding resistance alarm setting range Upper limit: 5~10A: 10.0~600mΩ; 10~20A: 10.0~300mΩ; 20~30A: 10.0~200mΩ; Lower limit: 0.0~100mΩ
  • Grounding resistance test time Range: 1~999s Resolution: 1s
  • Leakage current measurement setting Ground leakage current: G-L, G-N, AUTO (G-L, G-N)
  • Leak type setting Dynamic leakage, static leakage, optional built-in three body networks, free to switch, can customize any body network
  • AC voltage measurement range: 5.0V-300.0V, resolution: 0.1V, accuracy: ± (1.5% reading + 3V)
  • Leakage current measurement Range: 0.000mA-20.00mA, resolution: 0.001/0.01mA, accuracy ± (1.5% reading + 5 words)
  • Leakage current setting alarm range Upper limit: 0.001~20.00mA; lower limit: 0.000~20.00mA
  • Leakage current test time Range: 1~999s Resolution: 1s
  • AC power voltage measurement range: 5.0V-300.0V, resolution

Brand: Applent Instruments
 
Properties:

  • Joint testing of six functions of pressure, insulation, grounding, leakage, power and commissioning (6 of 5)
  • Equipped with a PLC control interface, a variable frequency power supply control interface, a communication interface, etc., they can be automatically tested by external supporting facilities.
  • Higher reaction and test speed, the minimum setting is 0.5 seconds;
  • 1.5-level safety test accuracy, 0.5-level electrical parameter test accuracy;
  • The lower limit can be set to prevent product defect detection; for product test failure, intelligent analysis, sound and light alarm.

Bond: housewares

  • AC output voltage Range: 100-5000V, 50Hz/60Hz dual frequency optional, resolution: 1V, accuracy ± (1.5% set value +3V)
  • Current measurement 0.002-9.999-40.00mA, resolution: 0.001mA/0.01mA, accuracy: ± (1.5% read +0.005mA)
  • Current alarm setting range Upper limit: 0.001-40.00mA, lower limit: 0.00-40.00mA
  • AC withstand voltage test time Range: 1 ~ 999s Resolution: 1s
  • DC output voltage Range: 100-1000V continuously adjustable, resolution: 1V, accuracy: ± (1.5% set value +3V)
  • Insulation resistance measurement 100-499V: <;100MΩ: ± (5% reading + 0.5MΩ); 100MΩ-1000MΩ: ± (10% reading + 5MΩ) 500-1000V: <;100MΩ: ± (2% reading + 0.2MΩ ); 100MΩ-3000MΩ: ± (5% reading + 2MΩ)
  • Insulation resistance alarm setting range Upper limit: 1 ~ 2000MΩ; Lower limit: 0 ~ 2000MΩ
  • Insulation resistance test time Range: 1 ~ 999s Resolution: 1s
  • Grounding resistance output AC current Range: 5-30A continuously adjustable output, 50/60Hz dual frequency optional, resolution: 0.01A accuracy: ± (2% set value +0.20A)
  • Grounding resistance measurement range Range: 10.0~600mΩ Accuracy: 1.5% reading +3mΩ, resolution: 1mΩ
  • Grounding resistance alarm setting range Upper limit: 5~10A: 10.0~600mΩ; 10~20A: 10.0~300mΩ; 20~30A: 10.0~200mΩ; Lower limit: 0.0~100mΩ
  • Grounding resistance test time Range: 1~999s Resolution: 1s
  • Leakage current measurement setting Ground leakage current: G-L, G-N, AUTO (G-L, G-N)
  • Leak type setting Dynamic leakage, static leakage, optional built-in three body networks, free to switch, can customize any body network
  • AC voltage measurement range: 5.0V-300.0V, resolution: 0.1V, accuracy: ± (1.5% reading + 3V)
  • Leakage current measurement Range: 0.000mA-20.00mA, resolution: 0.001/0.01mA, accuracy ± (1.5% reading + 5 words)
  • Leakage current setting alarm range Upper limit: 0.001~20.00mA; lower limit: 0.000~20.00mA
  • Leakage current test time Range: 1~999s Resolution: 1s
  • AC power voltage measurement range: 5.0V-300.0V, resolution