Properties:

  • Display = graphical
  • Limit value display = no
  • Protective conductor current = no
  • Touch current = no
  • Consumer current measurement = no

Binding: Electronics

Details:

Suitable for solar installers for initial start-up, repeat testing, troubleshooting, performance assessment, photovoltaic experts as well as service, cleaning and maintenance teams.

Testing of solar parks, power plants and large-scale systems with 1500 V technology. As part of the commissioning and repeat testing of grid-connected photovoltaic systems in accordance with VDE 0126-23 (DIN EN 62446), polarity tests, open circuit voltage and short-circuit current measurements of PV strings connected in parallel can be carried out, saved and documented safely and efficiently up to 1500 V / 40 A.

Simple operation via buttons with AUTO test sequence. Measured value memory for 999 photovoltaic strings and USB interface for measured value download in csv format.

  • Display - graphical.
  • Backlight of the LC display - yes.
  • Measurements: polarity check of the PV string.
  • Open circuit voltage Uo / c up to 1500 V DC.
  • Short circuit current Is / c up to 40 A DC.
  • Display and storage of the solar irradiation W / m2 and the PV module / environment

Brand: Benning

Properties:

  • Display = graphical
  • Limit value display = no
  • Protective conductor current = no
  • Touch current = no
  • Consumer current measurement = no

Binding: Electronics

Details:

Suitable for solar installers for initial start-up, repeat testing, troubleshooting, performance assessment, photovoltaic experts as well as service, cleaning and maintenance teams.

Testing of solar parks, power plants and large-scale systems with 1500 V technology. As part of the commissioning and repeat testing of grid-connected photovoltaic systems in accordance with VDE 0126-23 (DIN EN 62446), polarity tests, open circuit voltage and short-circuit current measurements of PV strings connected in parallel can be carried out, saved and documented safely and efficiently up to 1500 V / 40 A.

Simple operation via buttons with AUTO test sequence. Measured value memory for 999 photovoltaic strings and USB interface for measured value download in csv format.

  • Display - graphical.
  • Backlight of the LC display - yes.
  • Measurements: polarity check of the PV string.
  • Open circuit voltage Uo / c up to 1500 V DC.
  • Short circuit current Is / c up to 40 A DC.
  • Display and storage of the solar irradiation W / m2 and the PV module / environment