ET3505 - Digital LCR bench measuring device High-precision digital LCR bridge +/- 0.05% accuracy
Review: 5 - "A masterpiece of literature" by , written on May 4, 2006
I really enjoyed this book. It captures the essential challenge people face as they try make sense of their lives and grow to adulthood.

ET3505 - Digital LCR bench measuring device High-precision digital LCR bridge +/- 0.05% accuracy

Available: Out of Stock
€1.478,65

Brand: Unknown

Properties:

  • +/- 0.05% basic accuracy
  • Maximum 200 times / s measuring speed 
  • Frequency measuring range of ET3505: 10Hz ~ 500 kHz frequency range
  • Amplitude of the excitation signal 10 mV - 2 V adjustable
  • Internal programmable DC bias

Bond: housewares

Description: ET3505 LCR digital bridges are high-precision component parameter analyzers making use of automatic balancing bridge principle, featuring 10 Hz~ 500 kHZ testing bandwidth, continuously adjustable frequency, 0.05% of basic measuring accuracy, automatic level control, list scanning and position counting, which can provide accurate and complete measurement and analysis for most components and materials, so it is wildly used in product R&D, component incoming inspection and online product sorting.

  • 0.05% basic accuracy
  • A maximum of 200 time/s measuring speed
  • Frequency measurement range of 10 Hz- 100KHz, 0.05% basic accuracy, 6 1/2 digit display
  • Amplitude of excitation signal 10 mV- 2 V adjustable
  • Internal programmable DC bias voltage
  • External additional DC bias voltage supported
  • Automatic level adjustment of voltage or current
  • V,I testing signal monitoring
  • 10-point list scanning testing
  • 10-grade sorting and counting
  • 256 groups of correcting data for specified frequencies
  • 6 digit reading resolution
  • 7” LED display screen, Chinese and English interfaces
  • USB, Ethernet, RS232, GPIB, Handler interfaces

Brand: Unknown

Properties:

  • +/- 0.05% basic accuracy
  • Maximum 200 times / s measuring speed 
  • Frequency measuring range of ET3505: 10Hz ~ 500 kHz frequency range
  • Amplitude of the excitation signal 10 mV - 2 V adjustable
  • Internal programmable DC bias

Bond: housewares

Description: ET3505 LCR digital bridges are high-precision component parameter analyzers making use of automatic balancing bridge principle, featuring 10 Hz~ 500 kHZ testing bandwidth, continuously adjustable frequency, 0.05% of basic measuring accuracy, automatic level control, list scanning and position counting, which can provide accurate and complete measurement and analysis for most components and materials, so it is wildly used in product R&D, component incoming inspection and online product sorting.

  • 0.05% basic accuracy
  • A maximum of 200 time/s measuring speed
  • Frequency measurement range of 10 Hz- 100KHz, 0.05% basic accuracy, 6 1/2 digit display
  • Amplitude of excitation signal 10 mV- 2 V adjustable
  • Internal programmable DC bias voltage
  • External additional DC bias voltage supported
  • Automatic level adjustment of voltage or current
  • V,I testing signal monitoring
  • 10-point list scanning testing
  • 10-grade sorting and counting
  • 256 groups of correcting data for specified frequencies
  • 6 digit reading resolution
  • 7” LED display screen, Chinese and English interfaces
  • USB, Ethernet, RS232, GPIB, Handler interfaces