Gossen - Multimeter
Review: 5 - "A masterpiece of literature" by , written on May 4, 2006
I really enjoyed this book. It captures the essential challenge people face as they try make sense of their lives and grow to adulthood.

Gossen - Multimeter

Available: In Stock
€508,82

Brand: Gossen Metrawatt

Characteristics:

  • AC voltage measurement also "low resistance" (1 MΩ)
  • Switchable 1 kHz / -3 dB low-pass filter
  • TrueRMS bandwidth 10 kHz
  • Direct current measurement 100 µA - 10 A (16 A)

Binding: electronics

Details:

  • Display: ± 12,000 digits
  • TRMS up to 10kHz
  • 16 multimeter functions
  • VACTRMS, VAC + DC TRMS, VDC
  • Hz, resistance, continuity
  • diode, AACTRMS
  • AAC + DC TRMS
  • precision temperature indicator for K thermocouples,
  • additional filter function and low resistance Voltage measurement to limit interference, e.g. when taking measurements on frequency converters,
  • acoustic / optical signals for: continuity test,
  • voltages dangerous to touch,
  • exceeding overload limits,
  • storage of min / max values,
  • new housing design,
  • extra battery and fuse compartment
  • housing made of impact-resistant plastic, large illuminated display
  • 15mm digit height and analog bar graph
  • 3 sockets with patented ABS socket lock
  • water and dust proof IP52
  • measurement category 1000V CAT III and 600V CAT IV according to IEC 61010-1 2nd edition,

scope of delivery: cable set, battery and DKD calibration certificate

Features

  • * Display: analog / digital
  • * Analog bar display: Yes
  • * Multiple display: Yes
  • * Measuring range selection: manual / autom atic
  • * Max. voltage measuring range AC: 1000 V
  • * Lowest resolution alternating voltage: 1 mV
  • * Max. voltage measuring range DC: 1000 V
  • * Lowest resolution direct voltage: 100 mV
  • * Max. current measuring range AC: 10 A
  • * Lowest resolution alternating current: 100 µA
  • * Max. current measuring range DC: 10 A
  • * Smallest resolution direct current: 100 µA
  • * Max. Resistance measuring range: 10 MOhm
  • * Smallest resolution resistance: 0.01 Ohm
  • * Temperature measurement: Yes
  • * Capacitance measurement: No
  • * Frequency measurement: Yes
  • * Continuity test / diode test: Yes
  • * Nominal test voltage 10 V: No
  • * Nominal test voltage 50 V: No
  • * Nominal test voltage 100 V: No
  • * Nominal test voltage 250 V: No
  • * Nominal test voltage 500 V: No
  • * Nominal test voltage 1000 V: No
  • * With level measurement (dB): No
  • * Instantaneous value memory (data hold): Yes
  • * Maximum value memory: Yes
  • * Minimum value memory: Yes
  • * True effective value measurement (TRMS): Yes
  • * Duty cycle measurements: Yes
  • * Measured value memory: No
  • * ...

Brand: Gossen Metrawatt

Characteristics:

  • AC voltage measurement also "low resistance" (1 MΩ)
  • Switchable 1 kHz / -3 dB low-pass filter
  • TrueRMS bandwidth 10 kHz
  • Direct current measurement 100 µA - 10 A (16 A)

Binding: electronics

Details:

  • Display: ± 12,000 digits
  • TRMS up to 10kHz
  • 16 multimeter functions
  • VACTRMS, VAC + DC TRMS, VDC
  • Hz, resistance, continuity
  • diode, AACTRMS
  • AAC + DC TRMS
  • precision temperature indicator for K thermocouples,
  • additional filter function and low resistance Voltage measurement to limit interference, e.g. when taking measurements on frequency converters,
  • acoustic / optical signals for: continuity test,
  • voltages dangerous to touch,
  • exceeding overload limits,
  • storage of min / max values,
  • new housing design,
  • extra battery and fuse compartment
  • housing made of impact-resistant plastic, large illuminated display
  • 15mm digit height and analog bar graph
  • 3 sockets with patented ABS socket lock
  • water and dust proof IP52
  • measurement category 1000V CAT III and 600V CAT IV according to IEC 61010-1 2nd edition,

scope of delivery: cable set, battery and DKD calibration certificate

Features

  • * Display: analog / digital
  • * Analog bar display: Yes
  • * Multiple display: Yes
  • * Measuring range selection: manual / autom atic
  • * Max. voltage measuring range AC: 1000 V
  • * Lowest resolution alternating voltage: 1 mV
  • * Max. voltage measuring range DC: 1000 V
  • * Lowest resolution direct voltage: 100 mV
  • * Max. current measuring range AC: 10 A
  • * Lowest resolution alternating current: 100 µA
  • * Max. current measuring range DC: 10 A
  • * Smallest resolution direct current: 100 µA
  • * Max. Resistance measuring range: 10 MOhm
  • * Smallest resolution resistance: 0.01 Ohm
  • * Temperature measurement: Yes
  • * Capacitance measurement: No
  • * Frequency measurement: Yes
  • * Continuity test / diode test: Yes
  • * Nominal test voltage 10 V: No
  • * Nominal test voltage 50 V: No
  • * Nominal test voltage 100 V: No
  • * Nominal test voltage 250 V: No
  • * Nominal test voltage 500 V: No
  • * Nominal test voltage 1000 V: No
  • * With level measurement (dB): No
  • * Instantaneous value memory (data hold): Yes
  • * Maximum value memory: Yes
  • * Minimum value memory: Yes
  • * True effective value measurement (TRMS): Yes
  • * Duty cycle measurements: Yes
  • * Measured value memory: No
  • * ...